Exact Shipping Calculated When You Order

800-528-1417 / 480-464-2485

Serving Customers for Over 40 Years

sales@circuitspecialists.com

FLUKE 115 Field Service Technicians Digital Multimeter

Availability: Available For Back Order
Item: FLUKE 115
Quantity      Price
1      $ 148.190
Quantity :     0 In Stock
FLUKE 115 Field Service Technicians Digital Multimeter
 

Designed by electricians. Engineered by Fluke.

Compact true-rms digital multimeter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.

Features of the FLUKE 115 Digital Multimeter:

  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

Safety conformance

All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.

Specifications
Maximum voltage between any terminal and earth ground
  600 V
Surge protection
  6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
  33 segments, updates 32 per second
Operating Temperature
  -10 °C to + 50 °C
Storage Temperature
  -40 °C to + 60 °C
Battery type
  9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
  400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range: 600 ?
Resolution: 1 ?
Accuracy: Beeper on < 20 ?, off > 250 ?; detectsopens or shorts of 500 ?s or longer.
Ohms
Range/Resolution: 600.0 ? / 0.1 ?
Range/Resolution: 6.000 k? / 0.001 k?
Range/Resolution: 60.00 k? / 0.01 k?
Range/Resolution: 600.0 k? / 0.1 k?
Range/Resolution: 6.000 M? / 0.001 M?
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 M? / 0.01 M?
Accuracy: 5 % + 2
Diode Test
Range/Resolution: 2.00 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 µF
Accuracy: 5% + 20%
Lo-Z Capacitance
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
  20 A overload for 30-seconds max
DC amps
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
  20 A overload for 30-seconds max
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.9 Hz / 0.01 Hz
Range/Resolution: 9.999 kHz / 0.001 kHz
Range/Resolution: 50 kHz / 0.01 kHz
Accuracy: 0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage

Mechanical & General Specifications
Size
  167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
  550 g
Warranty
  3 years

Included Accessories

  • User’s manual
  • TL75 Hard Point Test Lead Set Holster
  • 9V battery (installed)

View Product Manual