We provide two versions of this JUMBO sized LCD display. The PM-1028A is designed to run off of a 9V (7-11V) independent power source while the PM-1208B 5V common ground version uses power from the power supply circuit of the instrument it is installed in. The figure height is 21mm. High quality SMT construction provides high reliability and the decimal point selection is conveniently done by wire jumpers. These panel meters implement dual slope integration A-D conversion measuring methods. The PM-1028A and PM-1028B come in an easy to install "snap-in" mountable bezel (typical rectangular hole size 88mm x 41mm). |
| Jumbo LCD 9V Independent Power Supply Version (PM-1028A) | ||
| Jumbo LCD 5V Common Ground Power Supply Version (PM-1028B) | ||
| Jumbo LCD 5V Common Ground Panel Meter w/ Back Light (PM-1028B-BACKLIT) | ||
Features
Possible Applications Voltmeter Thermometer PH Meter DB Meter Watt Meter Current Meter Capacitance Meter Lux Meter LCR Meter Other Industrial & Domestic Uses Specifications
Operation A) Select the max. measuring range and decimal point jumping as follows:
B) Connect 7-11V DC (independent for PM-1028A) or 5V DC (common gound, for PM-1028B) power supply to panel meter, pay special attention to proper polarity, independent or common ground power supply. C) For ranges other than 200mV, make the right selection, input accurate 2/3 x max Voltage generated by calibrator (Fluke 5500A, e.g. 100.0V for 200.0V range) and carefully compare against and adjust the semi-fixed resistor to have same reading in LCD. D) Connect the input voltage to be measured to VIN and GND. The input voltage should be DC only. |